uCT 780

uCT 780
160-slice CT

for Price / Quote
for Documentation
for Questions

With the persistent pursuit of precision and efficiency for imaging and diagnosis, uCT 780 is equipped with the fully integrated Z-Detector to allow low dose data acquisition with fine details. The fast rotation speed of the system improves the cardiac scan quality.

 

  • Innovative Z-Detector (Fine Sampling, Scintillating Detector Material, Ultra-low Noise Design)
  • Coordinated Control System Architechure (Rapid Transfer of Large Datasets, Real-time System Condition Monitor, System Hardware Synchronization Control on a Microsecond Basis)
  • Precision in Image Reconstruction (1024 x 1024 High-definition Reconstruction Matrix, Metal Artifact Correction, 0.5mm Thickness Images in All FOVs)
  • Excellence in Cardiac Imaging (CardioXphase, 100kW Max Generator Power, 0.3s Rotation Speed, Adaptive And Intuitive Applications)
  • Precision in Dose control (70kV Scan Mode, KARL 3D Iterative Denoising, Auto ALARA kVp)

Coordinated Control System Architechure

 
Rapid Transfer of Large Datasets

Supports the 360 million voxel data acquisition and reconstruction speed up to 60  IPS.

 
Real-time System Condition Monitor

High system reliability with enhanced serviceability.

 
System Hardware Synchronization Control on a Microsecond Basis

Supports precise radiation dose control and 0.3s high speed gantry rotation.

 

Precision in Image Reconstruction

 
1024 x 1024 High-definition Reconstruction Matrix

The high resolution reconstruction matrix reveals fine anatomical details such as internal auditory canal (IAC), small joints, and lung imaging.

 
Metal Artifact Correction

Metal Artifact Correction (MAC) reduces metal artifacts to improve image quality while preserving surrounding anatomical structures.

 
0.5mm Thickness Images in All FOVs

High resolution CT images reveal fine anatomical details.

 

Excellence in Cardiac Imaging

 
CardioXphase

Intelligent and adaptive phase selection.

 
100kW Max Generator Power

Clearly visualize challenging patient anatomy.

 
0.3s Rotation Speed

Improves the temporal resolution for cardiac imaging.

 
Adaptive And Intuitive Applications

Single-click post-processing to make image interpretation simpler.

 

Precision in Dose control

 

70kV Scan Mode

70kV scan mode can increase signal-to-noise ratio (SNR) to be especially beneficial for pediatric patients, contrast imaging and CT Venography (CTV) imaging.

 

KARL 3D Iterative Denoising

The state-of-the-art algorithm is performed in both the projection and image spaces to provide low dose, high quality images.

 

Auto ALARA kVp

uDose generates an optimized 3D dose distribution plan for every individual scan according to anatomical information.

 